Files
ShoeGaze/Tests
josh b4a04f6dc8 fix(amps): clamp Modern High-Gain sag gain (no phase inversion)
Review blocker: sag gain 1 - sag*envelope went negative because the envelope
follows the post-Presence/Depth-shelf signal, which exceeds 1 (shelves add up to
+8/+6 dB) — at high sag+presence+depth it phase-inverted loud content instead of
drooping (verified ~-1.0 correlation). Clamp the sag gain to [sagGainFloor(0.15),
1] so it always attenuates, never inverts. Doc/const nits fixed (per-const docs,
"switches" not "sweeps" for the binary Tight). Regression test asserts positive
correlation (no inversion) at presence/depth/sag maxed.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-08-03 16:25:26 -07:00
..